Non-return Explosion Valve - Q-FlapCompact II

Standard Operation

During operation the downstream mounted flap is kept open through the process air flow. In case of breakdown the flap is closed due its own wieght. Starting the system, the opening of the flap is damped.

 

Explosion Event

In case of an explosion the Q-FlapCompact II closes due to the pressure front spreading within the ductwork. The following explosion flame and the pressure cannot strike back the ductwork. Personnel working at capturing points or downstream system parts are protected against the explosion effects.

The flap damping element prevents the flap to open shortly after an explosion due the appearing low pressure. The passive non-return Q-FlapCompact II protects horizontal aspiration lines between a flow velocity between 15-30 m/s. Extensive research and testing under real explosion conditions enabled approval of the Q-FlapCompact II for St 1 or St 2 (max.KST-Value = 300 bar x m/s). Q-FlapCompact II is applicable for reduced pressure (Pred) up to 0,5 bar (7.25 psi)

 

Monitoring with Q-FlapCompact II Plus (optional)

Additionally the Q-FlapCompact II Plus offers a wear-and-tear sensor that monitors the abrasion that could possibly occur on the stainless steel flap. It is also equipped with an integrated clogging sensor that indicates any kind of product accumulation underneath the seats which ensures safe closing of the flap.

 

 

 